TUBE SERIES | TKA45 Unsupported arrangement
Inside heights
36
Unsupported length Lf
Inside widths 50 – 150
LS
Lf
LS 2
LS
z
Lf
hG
Driver
KR
t
LB
H
Hz
Fixed point
A sag of the cable carrier is technically permissible for extended movement ranges, depending on specific application.
UB
LS max. [m]
t [mm]
z [mm/m]
Dynamics
vmax [m/s] amax [m/s] unsupported gliding unsupported gliding
125
9
3
45
20 45.5
17
Installation measurements unsupported
KR [mm]
H [mm]
Hz [mm]
LB [mm]
UB [mm]
82 95
214 240 300 340 390 450 520
249 275 335 375 425 485 555
348 389 483 546 625 719 814
153 166 196 216 271 301
125 145 170 200 230
Load diagram for unsupported length Lf depending on the additional load
Calculation of the chain length
Chain length Lk
8.0
Lk = Ls + LB 2
6.0
Chain length Lk rounded off to pitch t
4.0
Lf = Ls - t 2 Unsupported length Lf
2.0
0
0 0.5 1.0 1.5 2.0 2.5 3.0 3.5 Unsupported length Lf in m
22
www.ustsubaki.com • 800-443-4216
Powered by FlippingBook