Dynamic Cable Carriers General Catalog

KC0900 RS  | Inner distribution | TS0 · TS1 · TS2

Divider systems The divider system is mounted on each crossbar as a standard – on every 2 nd chain link (HS – half-stayed).

As a standard, dividers or the complete divider system (dividers with horizontal shelves) are movable in the cross section (version A) .

Inner heights

58

Divider system TS0 without horizontal shelf

a x min [mm]

a c min [mm]

n T min

Vers. a T min [mm]

Inner widths

58

A

4.5 14 10 – The dividers can be moved in the cross section.

100 – 400

KR

a T

a x

a c

a T

14 4

Incre- ments

Divider system TS1 with continuous horizontal shelf

1 mm

VD1 VD2 VD3 VD4 VD5 VD23 VD45 VD415

a T max [mm]

a x min [mm]

a c min [mm]

n T min

Vers. a T min [mm]

11 11 12 12

12

12

A

19

19

7 25 14 10 2

4 1 5

27

35

2 3

42

12

26

The dividers can be moved in the cross section.

42

35

27

19

19

4

12

12

KR

a T

a x

a c

a T

14

4

Divider system TS2 with partial horizontal shelf

VR0 VR1 VR2 VR3 VR4 VR5 VR23 VR45 VR415

a x min [mm]

a c min [mm]

n T min

Vers. a T min [mm]

11 11 12 12

12

12

A

19

19

7 14 10 2 With grid distribution (1 mm grid) . The dividers are fixed by the horizontal shelf, the complete divider system is movable in the cross section.

4 1 5

27

35

2 3

42

58

12

26

42

35

27

19

19

4

12

12

KR

a T

a x

a c

a T

14

4

Order example

TS1

.

A

.

3

.

K1

.

34

-

VD1

K4

38

VD3

.

.

-

Divider system

Version

n T

Chamber

a x

Horizontal shelf

Please state the designation of the divider system (TS0, TS1,...) , the version, and the number of dividers per cross section [n T ]. In addition, please also enter the chambers [K] from left to right, as well as the assembly distances [a T /a x ]. If using divider systems with horizontal shelf (TS1 – TS2) , please also state the positions (e.g. VD23) viewed from the left moving bracket belt. You are welcome to add a sketch to your order.