Guide Channels | Installation Dimensions | Single Track
Single track arrangement – with lower drive connection and lowered mounting height (standard)
L Z2
L Z1
L S
L S 2
U B
RKR
Moving bracket
l 1
A
B
L B
KR
H
Slide support
Fixed bracket
A
B
L KA '
L KA
Calculating the channel length
Addition for connection Addition L Z2 L Z2 = ^ l 1 + 50 mm
Calculating the connection height Connection height H H = 3 h G
Addition for loop overhang Addition L Z1 L Z1 = ^ U B + 50 mm
Channel length L KA L KA = L S + L Z1 + L Z2
Single track arrangement – high connection
L Z1
L S
L Z2
L S 2
U B
l 1
Moving bracket
A
B
L B
KR
H
Slide support
Fixed bracket
A
B
L KA '
L KA
Calculating the channel length
Addition for loop overhang Addition L Z1 L Z1 = ^ U B + 50 mm
Addition for connection Addition L Z2 L Z2 = ^ l 1 + 50 mm
Channel length L KA L KA = L S + L Z1 + L Z2
The calculations for the cable carrier length and the length of carrier in bend can be found in the respective cable carrier chapter.
704