Dynamic Cable Carriers General Catalog

Alu Guide System  | Mounting Elements

Fastening: standard

Fastening: flowing joint

The internal or external mounting kits are mounted at the joints, ensuring precise connection of the joints in addi- tion to fastening the channel to the substructure.

The internal and external mounting kits are mounted with a spacing of 30-500 mm from the joints, ensuring fastening of the channel to the substructure.

1

2

min. 30 max. 500

min. 30 max. 500

min. 30 max. 200

Calculating C-profile length C-profile length L P L P = B KA + 90

2000

C-profile length L P rounded to 50 mm

Suitable perforated C-profiles can be found from page 733

External mounting kit 1  The mounting brackets are moun- ted at the outside of the channel. The additional joint connectors ensure precise connection of the joints.

Internal mounting kit 2  The mounting brackets are moun- ted at the inside of the channel. The additional joint connectors ensure precise connection of the joints.

2 x

2 x

Multi-fastening kit

As a standard, the mounting kits included with the delivery are installed on all joints as well as at both ends of a channel. If you require more angle brackets beyond this, please state this when ordering.

for chain types K0650, M0650, M0950 and Q080 The multi-fastening kit for fixed bracket ensures optimum fas- tening of the cable carrier in the channel.

Order

To order the Steel Guide System , please provide the following information: ■ ■ Number of guide channels ■ ■ Total length of channel ■ ■ Support length L KA ' ■ ■ Type of fastening (internal/external) ■ ■ Delivery (unmounted/mounted) ■ ■ Support height h 1

■ ■ Fixing with C-profile ■ ■ Lift-stop device for cable carrier ■ ■ Inner width of guide channel b 1

731