Zip Chain Actuator

SPECIFICATIONS AND ENVIRONMENTAL REQUIREMENTS

ZCA main unit

ZCA25N

Forged steel ZCA35N

ZCA45N

Material Coating Color Lubricant Material Coating Color Material

Drive section

Black, Munsell N2.0 equivalent

Polyacetal Purple grey Munsell 0.8P6.3/3.0 equivalent (molded)

Black, Munsell N2.0 equivalent Iron

Housing section

Iron Shell Alvania EP Grease 2 [Showa Shell Sekiyu K. K.] * This grease is applied before shipment. 0 to 60°C 85% or less (no condensation)

Chain

Operating temperature

Ambient atmosphere Relative humidity

Environmental requirements

ZCA can be installed with any direction, be sure to mount a linear guide in the direction of travel. A mounting base is required to suspending installation. Typical rain-free indoor environment with dust levels kept at a general factory level.

Installation direction

CHARACTERISTICS WITHOUT BELLOWS

Input shaft

Maximum speed

Approximate mass

Zip Chain travel distance per input shaft rotation

Allowable thrust* 2 {kgf} N

Allowable stroke* 1

Model

Input shaft Dual shafts

Suspending Installation

Allowable torque N•m {kgf•m}

Allowable OHL

Input shaft rotation

Input shaft Standard/reverse shaft

Thrust direction

mm

N

{kgf}

mm/sec (r/min)

mm

kg

1.9 2.5 5.1 6.5 7.5 21 25 30

2.0 2.6 5.5 7.0 8.0 21 25 30

2.5 3.1 6.0 7.5 8.5

030

300 500 500 750

400 300

{40.8} {33.6}

1000

630

95.3

9.41 {0.96}

638 {65}

ZCA25N

050 050 075 100 100 150 200

1000 {102}

ZCA35N

1000

420

142.9

34.7 {3.53}

946 {96.4}

1000 1000 1500 2000

600 {61.2}

22 27 31

2000 {204}

125

240

ZCA45N

116.6 {11.9}

2065 {210.5}

500

1200 {122.5}

WITH BELLOWS *

Input shaft

Maximum speed

Approximate mass

Zip Chain travel distance per input shaft rotation

Allowable thrust* 2 {kgf} N

Allowable stroke* 1

Model

Input shaft Dual shafts

Suspending Installation

Allowable torque N•m {kgf•m}

Allowable OHL

Input shaft rotation

Input shaft Standard/reverse shaft

Thrust direction

mm

N

{kgf}

mm/sec (r/min)

mm

kg

2.5 3.1 5.5 7.0 8.0

2.6 3.2 6.0 7.5 8.5

3.1 3.7 6.5 8.0 9.0

030

300 500 500 750

400 300

{40.8} {30.6}

1000

630

95.3

9.41 {0.96}

638 {65}

ZCA25N

050 050 075 100 100 150 200

1000 {102}

ZCA35N

1000

420

142.9

34.7 {3.53}

946 {96.4}

1000 1000 1500 2000

431 {44}

22 27 32

22 27 32

23 28 33

2000 {204}

500

125

240

ZCA45N

116.6 {11.9}

2065 {210.5}

900 {91.8}

*1 Use the unit within the allowable stroke range. Also, be sure to always attach a linear guide in the direction of travel. *2 Values are obtained when operated at a maximum acceleration of 0.35 G (upper limit) with the end fitting attached. These values are applicable regardless of the type of installation (vertical, horizontal, suspending). *Made-to-order options